Flashlink Compact II Rev. A
nevion.com | 10
2.1.4 FC-3G-OE-36
Power A indicator: Gives status on power supply connected to the Power A connector on
the back side.
Green: Power supply connected
Orange: No or none working power supply connected
Red: The lower converter is malfunctioning. Please contact
Nevion support for advice.
Power B indicator: Gives status on power supply connected to the Power B connector on
the back side.
Green: Power supply connected
Orange: No or none working power supply connected
Red: The lower converter is malfunctioning. Please contact
Nevion support for advice.
1 to 18 indicators: Gives status per SFP converter channel.
Green: Valid input signal and reclocker in lock or bypass.
Orange: Signal on input, but reclocker not in lock.
Red: No valid input signal.
No light: No valid Nevion SFP present.
Upper SFP: Cage for fitting dual receivers non-MSA SFPs.
Lower SFP: Cage for fitting dual receivers non-MSA SFPs.